Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Patient Monitor |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. 12.1'' color TFT LCD screen, High brightness, Wide viewing, 8 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
2. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
3. Streamlined outline design with sense of the times & foldable handle.
4. Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower.
5. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
6. Suitable for adults, pediatrics and neonates
7. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
8. Printing of data, waveform, trend tables and trend diagram. 9. Optional CO2 detection function
ECG |
Heart rate(HR) Measurement range: 30BPM ~ 350BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error: Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10% |
NIBP |
Measurement range: Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2% |
IBP |
Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable) Respiration Rate Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 % |
Temperature |
Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ºC~ 45.0ºC Accuracy: ± 0.2 ºC Response time: ≤ 3 min. |
GMI SpO2 |
Display type: Waveform, data Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm |
Pulse Rate |
Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2% Trend review: Can Review history data of 360 hours |
CO2 |
Measurement range: 0%~ 10.0%( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5% Measured values) 10%(>5% Measured values) |
Details | Standard packaging for export;
MOQ:1pc; CE/ISO certification;
|