Customization: | Available |
---|---|
Classification: | Physiological Functions of Diagnosis and Monitoring Equipment |
Certification: | CE, ISO13485 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Display | 12.1 inch color TFT Touch Screen |
Resolution | 800X600 |
Trace | 12 waveforms |
Sweep speed | 12.5mm/s, 25mm/s, 50mm/s |
Power | AC100-250V, 50/60Hz |
Temperature | 40C |
Humidity | 15-85% |
Patient Range | Adult, Pediatric, Neonate |
Indicator | Power indicator light |
Battery indicator light | |
Interface | Parameter cable interface |
AC power input socket | |
Network interface | |
External VGA interface | |
Alternate Display | |
Battery | Lithium-ion battery/ Rechargeable |
Trend time | 1~120hours |
Alarm | User-adjustable High and Low |
Audible and visual alarm | |
Recorder | Built-in, thermal array |
Record mode | Manual, on alarm, time-defined |
Print speed | 12.5mm/s, 25mm/s, 50mm/s |
Standard Configuration | IPX1 level waterproof cabinet |
12.1" Touch Screen with Handwriting Pen function | |
CardioTec 12-leads ECG/HR | |
OxiMax SpO2, | |
RESP | |
PR | |
TEMP | |
EtCO2 Socket Reserved | |
Nurse Call System, | |
lin-ion Battery | |
NIBP | |
Optional | (1)Dual TEMP, (2)Thermal Recorder, (3)Ne*llcor SpO2, (4)7-lead ECG, (5)Single/Double IBP, (6)Mainstream/Sidestream EtCO2, (7)ICG, Anesthesia Gas, (8)CF Card,(9)Optional Accessories for Neonate, Pediatric and Adult |
ECG
5 Leads: RA, LA, LL, RL, V
Lead mode: AVR, AVL, AVF, V
Gain: × 1.25mm/mV,2.5mm/mV,
5.0mm/mV, 10mm/mV,
20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,
50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Sensitivity: >200 μ V P-P
CMRR: ≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential: ±300mV
Polarization Voltage: ≥ ± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1mV ± 5%
NIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~ 240bpm
Measure & alarm range: Adult
SYS 40 ~ 280mmHg
DIA 10 ~ 220mmHg
MEAN 20 ~ 240mmHg
Pediatric
SYS 40 ~ 220mmHg
DIA 10 ~ 160mmHg
MEAN 20 ~ 170mmHg
Neonatal
SYS 40 ~ 135mmHg
DIA 10 ~ 100mmHg
MEAN 20 ~ 110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy: ± 3mmHg
Resolution: 1mmHg Accuracy:
Max. Mean Error: ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult 300mmHg
Pediatric 240mmHg
Neonatal 150mmHg
SpO2
Measurement range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ± 2%
40% ~ 69% ± 3%
Pulse Rate
Measure/alarm range: 20 ~ 300bpm
Resolution: 1bpm
Accuracy: ± 3bpm
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3 ~ 3 Ω
Base Impedance range: 200 Ω ~ 4000 Ω
Bandwidth: 0.3 ~ 2.5Hz
Gain: × 0.25, × 0.5, × 1, × 2, × 4
Resp rate:
Measurement Range
Adult 0 ~ 120BrPM
Neonatal/Pediatric 0 ~ 150BrPM
Resolution: 1BrPM
Accuracy: 7 ~ 150BrPM ( ± 2BrPM)
0 ~ 6BrPM (unspecified)
Apnea Alarm: 10 ~ 40s
TEMP
Channel 2
Measure & alarm range: 0 ~ 50 ºC
Resolution: 0.1 ºC
Accuracy (no sensor): ±0.1 ºC (0~50 ºC)
Standard accessories
NIBP cuff & tube
ECG cable & electrodes
SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator's manual
Optional accessories
Trolley bracket
Hanging bracket
Monitor recorder
Vehicle-mounted power supply