Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
Application:
Full support perspective, gastrointestinal spot film, GI (barium meal, barium enema), orthopedic photography, pediatrics photography, chest, urinary system angiography, peripheral angiography operations, gynecological Photography (HSG) and many other checks, the real machine can realize all these function.
Main Specifications:
Item |
Content |
Technical parameter |
|
Power supply |
Voltage |
380V±38V |
|
Frequency |
50Hz±1Hz |
||
Capacity |
≥65kVA |
||
internal resistor |
≤0.17Ω |
||
Digital X-ray high voltage system (import high-frequency generator )
|
photography |
Power Output |
80KW |
Inverter Frequency |
440KHZ |
||
Tube Voltage |
40kv-150kv step regulation |
||
Tube Current |
10mA-1000mA step regulation |
||
Exposure time |
1.0s-10000ms step regulation |
||
Control interface |
Touched LCD |
||
Control hand |
One-button operation handle |
||
fluoroscopy |
Tube Voltage |
40kv-120kv ontinuous regulation |
|
Tube Current |
0.5mA-6mA continuous regulation |
||
Digital Controlled X-ray Tube
|
Tube Brand |
Toshiba |
|
Tube Focus:Large Focus/Small Focus |
1.2mm /0.6mm |
||
Input Power |
Large focus: 80KW small focus: 50kW |
||
thermal capacity |
400 KHU |
||
Rotary anode speed |
9700rpm |
||
Micro-computer control remote diagnostic table
|
Material of the tabletop |
high strength,low absorb carbon fiber |
|
Rotation of the table |
90°~0°~-25° |
||
Transverse travel of table |
±110mm |
||
Longitudinal travel of the photography holder and film spot device |
≥720mm |
||
X-ray Focus-film gauge |
1100 mm-1500 mm |
||
Rotating foot plate |
±360° rotation |
||
Full film photography size |
8×10-14×17 |
||
Compressor force |
80N-130N |
||
Dividing method for spot film |
Full film, half dividing, three parts dividing, four parts dividing |
||
Control method for diagnostic table |
Remote,table control,frequency conversion soft starting and stopping |
||
beam limiter |
Electric Multi-leaf |
||
fixed bucky device for table |
Grid density: 103L/INCH, Grid ratio: 10:1,focusing distance: 120cm,fixed type: 15×18 |
||
Intensifier and CRT Monitor |
Image Intensifier |
Toshiba (9"/6"/4.5″) Image Intensifier |
|
high resolution CCD (digital cameras) |
ultra-low-light,standard 2000,000 pixel |
||
Monitor (Optional ) |
14medical high definition monitor, horizontal central resolution ratio :1000 lines,fringe: 800 lines,video bandwidth: 12.5MHz,50bit,image number/second: 25 frame |
||
workstation |
i5-6500(3.20 GHz),4 GB DDR3, 500GB SATA (7200 rpm), work list ; DSI function; Gather and deal with image ;Spot Film Acquire Image ;Image Playback ;Rich Image Processing Function ;X-ray Film Printer Function : Report Edit and Print Function ; |
||
LCD colorful screen |
19" LED Medical Use High Definition Monitor |
Standard Configuration:
Standard configuration:: |
|
Remote console (with touch screen control) |
1 set |
high-voltage generator |
1 set |
Toshiba X-ray Tube |
1set |
Electric multi-leaf collimator |
1 set |
Diagnostic Bed |
1set |
Thales Three Field image intensifier |
1set |
CCD Camera |
1set |
Medical HD monitor |
1set |
High voltage cable |
2sets |
workstation |
1set |