• Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
  • Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
  • Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
  • Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
  • Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
  • Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

Theory: Autoclave
Type: Pressure Steam Sterilization Equipments
Certification: CE, FDA, ISO13485
Electric Tension: 220V
LCD Display: With LCD Display
Ultra High Temperature Alarm: Ultra High Temperature Alarm
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
XrAS-90YDA/150YDA/200YDA/280YDA/400YDA/500YDA
Sterilization Information Recording and Printing
Without Sterilization Information Recording and Printing
Material
Stainless Steel
OEM
Available
Working Pressure
0.22MPa
Timer Scope
0~60min
Working Temperature
134 Degree
Power Supply
220V, 50kHz
Certificate
Ce ISO
ODM
Available
Warranty Period
2 Years
After-Sales Service
Whole Using Lifetime
Transport Package
Wooden Case
Specification
300mmx100mmx70mm
Trademark
XINDRAY MEDICAL
Origin
China
Production Capacity
10000

Product Description

Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer 
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

 

Features:

Automatic control of sterilization process without supervision, easy to apply
With drying function, to achieve sterilization drying effect
With over-temperature,over-pressure auto-protect device
Door safety lock system:when the door is not closed well, the steam can not enter the inner layer of the main body and alarm. The pressure in the sterilization Chamber is greater than 0.027MPa, the door was locked, can't open the door
Overpressure protection:when the pressure exceeds the working pressure ,the safety valve would reduce the pressure automatically
Low water protection devices:when the water does not reach the high level,the sterilizer will not start.Low water level will cut off the power to protect.
Over current protection:When current overload, the power supply circuit breaker will automatically cut off  the power supply
Fully stainless steel structure

Specifications:
 
MODEL TECHNICAL DATA 150YDA 200YDA 280YDA 400YDA 500YDA
Sterilizing chamber volume 150L
φ440×1000mm
200L
φ515×1000mm
280L
φ600×1000mm
400L
Φ700×1100mm
500L
Φ700×1300mm
Working pressure 0.22 MPa
Working temperature 134°C
Adjustment  of 
temperature
40°C - 134°C
Time of sterilization 0-60 min
Time of drying 0-60 min
 Heat average ≤± 2°C
 Power 9KW/380V 50Hz 9KW/380V 50Hz 12KW/380V 50Hz 18KW/380V 50Hz 18KW/380V 50Hz
Overall dimension(mm) 1400×600×1300 1400×670×1650 1400×770×1780 1430×880×1830 1800×900×1820
Transport dimension(mm) 1550×750×1850 1560×820×1850 1680×920×2100 1600×1050×2100 1850×1050×2100
G. W/N.W 320/240 KG 350/260 KG 465/365 KG 530/420 KG 580/470 KG

Hospital and Clinic Laboratory Large Horizontal Steam Autoclave SterilizerHospital and Clinic Laboratory Large Horizontal Steam Autoclave SterilizerHospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
 
Certificate:
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

Package:
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

Shipping:
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer

Our Service:
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer
Hospital and Clinic Laboratory Large Horizontal Steam Autoclave Sterilizer



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now