Item |
Specification |
1. High voltage generator |
1.1 |
standard output power:5.6kW |
1.2 |
mA range:10-100mA |
1.3 |
Tube voltage range:40-125kV |
1.4 |
mAs range :0.1-200mAs |
1.5 |
Load time range:0.002s~4s |
1.6 |
High voltage transformer structure:The power frequency |
2.X-ray tube |
2.1 |
Focus range:0.6/1.8mm |
2.2 |
Anode types: fixed anode |
2.3 |
The maximum voltage:125kV |
2.4 |
Anode angle 15° |
2.5 |
The inherent filtration:0.6mm Al/75kV |
3. Collimator |
3.1 |
The inherent filtration:1 mm Al /70 kV; |
3.2 |
Collimator is equipped with LED lights(Bright 30S are automatically extinguished) |
3.3 |
Collimator is built into measuring ruler |
4. The tube bracket structure |
4.1 |
SID: 330 ~ 1650mm |
4.2 |
Size after folding:1060*400*400mm |
4.3 |
weight:32KG |
5. Detector(iRay) |
5.1 |
WIFI connection, Amorphous Silicon oxide ,whole panel technology |
5.2 |
The effective camera size of the detector:350mm×430mm |
5.3 |
Pixel size:150 µm |
5.4 |
Gathering matrix:≥2304×2800pixels |
5.5 |
Spatial resolution≥3.4lp/mm |
5.6 |
Pixel gray level:≥14bit |
5.7 |
Detector cooling mode: natural cooling |
6. Digital image workstation |
6.1 |
CPU frequency:CORE i3 |
6.2 |
Memory capacity:4GB |
6.3 |
Hard drive capacity:500 GB |
6.4 |
64 bit Windows operation system |
7. Image acquisition software |
7.1 |
Patient registration: acquisition, find the patient data, to prepare for the photography |
7.2 |
Images display, image analysis, processing and output |
7.3 |
Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0,5.4AH |
7.4 |
System diagnosis: monitoring system status, diagnosis of the system fault |
8. Battery |
8.1.1 |
Power supply way |
8.1.2 |
Lithium battery supply |
8.1.3 |
The rated capacity:32.4V |
8.2 |
Battery capacity: More than 100 exposures, (Exposure conditions: 50kV,80mA,20ms ) |
8.3 |
Dual power supply, exposure under either wall current or lithium battery |
8.4 |
Maximum charging 4 hours |
8.5 |
The standby time is not less than 7 hours |
8.6 |
Can support handswitch and remote control exposure |
9. The machine parameters |
9.1 |
Appearance size |
9.1.1 |
Whole machine width:240 mm |
9.1.2 |
Whole machine length:440 mm |
9.1.3 |
Whole machine height:236 mm |
9.2 |
Whole weight(no detector):18kg |
10. Options |
10.1 |
Wireless network data transmission(WIFI) |
10.2 |
Choose a chest rack |
10.3 |
The selection of moving flat bed |