• Medical Hospital High Frequency 500mA 50kw X-ray Machine
  • Medical Hospital High Frequency 500mA 50kw X-ray Machine
  • Medical Hospital High Frequency 500mA 50kw X-ray Machine
  • Medical Hospital High Frequency 500mA 50kw X-ray Machine
  • Medical Hospital High Frequency 500mA 50kw X-ray Machine
  • Medical Hospital High Frequency 500mA 50kw X-ray Machine

Medical Hospital High Frequency 500mA 50kw X-ray Machine

Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: CE, MSDS, ISO13485
Group: All People
Output Power: 40kw
Radiography Tube Current: 10-500mA
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Xrx-HFMB500
Power Supply
220V, 50kHz
Inverter Frequency
50kHz
Radiography Tube Voltage
40-150kv
Battery
Available Lithium
Touch Screen
Available
Operation Method
Wire/ Wireless Control
After-Sales Service
Whole Using Lifetime
Transport Package
Wooden Case
Specification
650cm*300cm*190cm
Trademark
XINDRAY MEDICAL
Origin
China
Production Capacity
10000

Product Description

Medical Hospital High Frequency 500mA 50kw X-ray Machine
Medical Hospital High Frequency 500mA 50kw X-ray Machine

Features:

1. With high frequency inverter to emit high quality X-ray and low dose on  skin, and ensure excellent definition and contrast of pictures. 

2. With techniques of KV analog closed loop control, mAs digital closed loop control and micro-processing real-time control to ensure precision and repeatability of the dose. 

3. With kV, mAs two button adjustment, LCD display, multifunction of safety guard.
 
4. With 50 preset exposure programs, and can be modified and stored by the user for convenient operation. 

5. With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator. 

6. With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.


Specifications:

Item Specification
1.X- ray High voltage generator
1.1 Standard output power:40kW  
1.2 mA range:10-500mA
1.3 Tube voltage range:40-150kV
1.4 mAs range :0.1-250mAs
1.5 Load time range:0.001s~6.3s
1.6 Input voltage:450VDC/48VDC±10%
1.7 High voltage output master frequency:50kHz±5%
1.8 High voltage transformer structure:The power frequency
2.X-ray tube
2.1 Focus range:0.6/1.2mm
2.2 Anode heat capacity :150kHu
2.3 Anode types: rotating anode, maximum speed: 3200 revolutions per minute
2.4 Pipe sleeve heat capacity: 1250kHu
2.4 The maximum voltage:150kV
2.5 The anode input power:Big focus:50kW ,Small focus:22kW
2.6 Anode angle 12°
2.7 The inherent filtration:1.3mm Al/75kV
3. Collimator
3.1 The inherent filtration:1.0 mm Al /75 kV;
3.2  Collimator is equipped with LED lights(Bright 30s are automatically extinguished)
3.3 Collimator is built into measuring ruler
4. The tube bracket structure
4.1 X-ray tube support way: Folding arm
4.2 Tube focus distance to the ground:507mm~2000mm,±5%
4.3 Arm's  Folding Range :±60°
4.4 Tube Tilting Angle:±90°
4.5 Tube Vertical Rotation Angle:-30°~+90°
4.6 Collimator axial rotation  :±360°
5. Detector
5.1 WIFI connection ,Amorphous Silicon ,whole panel technology
5.2 Detector valid exposure size :350×430mm
5.3 Pixel size:150 µm
5.4 The effective camera size of the detector:14×17inch
5.5 Gathering matrix:≥2304×2800pixels;
5.6 Spatial resolution≥3.4lp/mm
5.7 Pixel gray level:≥14bit
5.8 Detector cooling mode: natural cooling
6. Digital image workstation
6.1 CPU frequency:CORE i3
6.2 Memory capacity:4GB
6.3 Hard drive capacity :500 GB
6.4 Display size: 17 inch LCD touch screen
6.5 Display screen Maximum resolution≥1280×1024;
6.6 64 bit Windows operation system
7. Image acquisition software
7.1 Patient registration: acquisition, find the patient data, to prepare for the photography
7.2 Radio graphic examination:setting system parameters, exposure photography and get the image
7.3 Images display, image analysis, processing and output
7.4 Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0
7.5 Configure calibration: the system components such as flat-panel detector, such as tube for automatic configuration and calibration
7.6 System diagnosis: monitoring system status, diagnosis of the system fault
7.7 Image Printing: Image Output to Film Printer
8. Battery
8.1 Power supply way
8.1.1 Lithium battery power supply
8.1.2 The rated capacity:46.8V,10.8Ah(Lithium battery meets UN38.3 standard requirements)
8.1.3 Battery capacity: More than200 exposures, chest image dosage (exposure conditions: 120 kv, 100 mA, 20ms )
8.2 Dual power supply, exposure under either wall current or lithium battery
8.3 Maximum charging 4 hours
8.4 Can support hand switch and remote control
9. The machine parameters
9.1 Appearance size:1560 mm×650 mm×1490 mm
9.2 Whole weight (no detector):220kg
10. External interface
10.1 Display interface(DVI)
10.2 Wireless network data transmission(WIFI)
10.3 Cable network interface
10.4 USB(2)
11.Options
11.1 Chest rack
11.2 Moving flat bed


Certificate:
Medical Hospital High Frequency 500mA 50kw X-ray Machine

Package:
Medical Hospital High Frequency 500mA 50kw X-ray Machine

Shipping:
Medical Hospital High Frequency 500mA 50kw X-ray Machine

Our Service:
Medical Hospital High Frequency 500mA 50kw X-ray Machine
Medical Hospital High Frequency 500mA 50kw X-ray Machine



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now