Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | Patient Monitor |
Certification: | CE, MSDS, ISO13485 |
Medical Device Regulatory Type: | Type 1 |
Display: | 8.4 Inch Color TFT LCD Screen |
Trace: | 7 Waveforms |
Customization: |
---|
Suppliers with verified business licenses
Features:
1. 8.4'' color TFT LCD screen, High brightness,Wide viewing, 7 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
2. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.
3. User-friendly and man-machine dialogue interface with pop-up menus, dialogue boxes, rotary mouse and etc. Low-power consumption design with standby mode, rechargeable high-energy built-in battery.
4. Drug calculation, ST-segment detection, pace maker and arrhythmia analysis.
5. Display format include OxyCRG diagram, 7-lead ECG waveform, big-font mode simultaneously ; can store 5 kinds of user-defined display format;
6. Sound and light integrated alarm, Alarm parameters can be adjusted to upper or lower.
7. Suitable for adults, pediatrics and neonates
8. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible.
9. Printing of data, waveform, trend tables and trend diagram.
10. Optional CO2 detection function
ECG |
Heart rate(HR) Measurement range: 30BPM ~ 300BPM; Accuracy: 1 BPM or ±1 %. Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10% Noise level: ≤ 30μV ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10% |
NIBP | Measurement range:
Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%, |
IBP |
Measurement range: -1.3~40KPa(-10 ~ 300mmHg) Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg Unit display: kPa or mmHg( selectable) |
Respiration Rate |
Measurement range: 0 BPM ~ 120 BPM; Accuracy: ±1 BPM or ±5 % |
Temperature |
Number of channels: 2 Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit Measurement range: 25.0 ºC~ 45.0ºC Accuracy: ± 0.2 ºC Response time: ≤ 3 min. |
SpO2 |
Display type: Waveform, data Measurement range: 0~100% Resolution: 1 BPM Pulse rate range: 30~250bpm Accuracy: ±1bpm |
Pulse Rate |
Measurement range: (30 ~ 250)bpm; Accuracy: 1BPM or ±2% |
Trend review | Can Review history data of 360 hours |
CO2 |
Measurement range: 0%~ 10.0%( Carbon dioxide inhalation and carbon dioxide exhalation) Accuracy: ±2mmHg(<5%Measured values) 10%(>5%Measured values) |